Identify your appliance
Models and ranges ATAG Selected references from manufacturer documentation, including older generations. Check the full name and suffix on the rating plate: manuals and error codes can differ by version and country.
Boiler display
ATAG error codes Check the model, note the full code and learn the useful precautions before the diagnosis.
Before reading the list Verified selection for ATAG iC / iS. Codes are not universal: confirm the model and generation in the exact manual.
Official manufacturer sources 15 error codes found
10 Outdoor sensor fault A temperature sensor is sending an impossible value: a faulty sensor, or a loose or short-circuited cable or connector. CautionView details 20 Flow sensor fault A temperature sensor is sending an impossible value: a faulty sensor, or a loose or short-circuited cable or connector. CautionView details 40 Return sensor fault A temperature sensor is sending an impossible value: a faulty sensor, or a loose or short-circuited cable or connector. CautionView details 50 DHW sensor fault (iC) A temperature sensor is sending an impossible value: a faulty sensor, or a loose or short-circuited cable or connector. CautionView details 61 Bus communication fault A control, communication or electronic memory fault has been detected: circuit board, controller, wiring or power supply. CautionView details 78 Water pressure reading out of range A control, communication or electronic memory fault has been detected: circuit board, controller, wiring or power supply. CautionView details 105 Venting programme active after power-on This display describes the appliance’s normal operating state (standby, pump pre-run, ignition, burner running…). It is not a fault. NormalView details 110 Safety temperature exceeded A temperature safety has tripped: the water is not circulating enough (air, pump, closed valves, dirty filter or heat exchanger) or the circuit is short of water. CautionView details 111 Maximum pressure exceeded The circuit pressure is too high: overfilling, a worn expansion vessel or strong heating of the circuit. CautionView details 117 Excessive pressure or pump pressure rise The circuit pressure is too high: overfilling, a worn expansion vessel or strong heating of the circuit. CautionView details 118 Insufficient pressure or pump pressure rise The water pressure in the heating circuit is too low, often because of a small leak, recent radiator bleeding or a slow loss over the months. CautionView details 129 Fan fails to start The fan is not running at the expected speed or does not stop: a dirty or worn fan, wiring or the electronic control. CautionView details 133 No flame after five attempts The burner failed to light or the flame was not detected: interrupted gas supply, worn ignition or sensing electrode, gas valve or condensate drain. CautionView details 151 Fan speed control or control unit fault A control, communication or electronic memory fault has been detected: circuit board, controller, wiring or power supply. CautionView details 154 Flow temperature rises too rapidly Water circulation is insufficient or detected as abnormal: air in the circuit, a blocked or weak pump, closed valves or a dirty circuit. CautionView details See the ATAG codes