Identify your appliance
Models and ranges Viessmann Selected references from manufacturer documentation, including older generations. Check the full name and suffix on the rating plate: manuals and error codes can differ by version and country.
Boiler display
Viessmann error codes Check the model, note the full code and learn the useful precautions before the diagnosis.
Before reading the list Meanings vary between Vitodens ranges and their controllers. Check the full screen and the model’s manual.
15 error codes found
0A Insufficient gas pressure The gas pressure or flow to the appliance is insufficient: a closed valve, the meter or network, or a gas safety component. CautionView details 0F Servicing required The appliance is signalling that servicing is due (interval reached, descaling or periodic check). This is usually not a fault. NormalView details A2 Insufficient pressure in the system The water pressure in the heating circuit is too low, often because of a small leak, recent radiator bleeding or a slow loss over the months. CautionView details A4 Pressure too high in the system The circuit pressure is too high: overfilling, a worn expansion vessel or strong heating of the circuit. CautionView details A8 Air detected in the circulation pump Water circulation is insufficient or detected as abnormal: air in the circuit, a blocked or weak pump, closed valves or a dirty circuit. CautionView details A9 Circulation pump blocked Water circulation is insufficient or detected as abnormal: air in the circuit, a blocked or weak pump, closed valves or a dirty circuit. CautionView details E3 Fault in the safety chain A temperature safety has tripped: the water is not circulating enough (air, pump, closed valves, dirty filter or heat exchanger) or the circuit is short of water. CautionView details F0 Internal electronics error A control, communication or electronic memory fault has been detected: circuit board, controller, wiring or power supply. CautionView details F1 Flue gas overheating A temperature safety has tripped: the water is not circulating enough (air, pump, closed valves, dirty filter or heat exchanger) or the circuit is short of water. CautionView details F2 Safety temperature limiter tripped A temperature safety has tripped: the water is not circulating enough (air, pump, closed valves, dirty filter or heat exchanger) or the circuit is short of water. CautionView details F3 Flame signal at burner start The appliance detects a flame when the burner should be off, or after the gas has closed. The gas valve or the sensing circuit may be faulty. DangerView details F4 No flame signal The burner failed to light or the flame was not detected: interrupted gas supply, worn ignition or sensing electrode, gas valve or condensate drain. CautionView details F8 Gas valve closes too late The appliance detects a flame when the burner should be off, or after the gas has closed. The gas valve or the sensing circuit may be faulty. DangerView details F9 Fan too slow at burner start The fan is not running at the expected speed or does not stop: a dirty or worn fan, wiring or the electronic control. CautionView details FA Fan not stopped when the burner is off The fan is not running at the expected speed or does not stop: a dirty or worn fan, wiring or the electronic control. CautionView details See the Viessmann codes